Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(22)2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34833788

RESUMO

Attention and awareness towards musculoskeletal disorders (MSDs) in the dental profession has increased considerably in the last few years. From recent literature reviews, it appears that the prevalence of MSDs in dentists concerns between 64 and 93%. In our clinical trial, we have assessed the dentist posture during the extraction of 90 third lower molars depending on whether the operator performs the intervention by the use of the operating microscope, surgical loupes, or with the naked eye. In particular, we analyzed the evolution of the body posture during different interventions evaluating the impact of visual aids with respect to naked eye interventions. The presented posture assessment approach is based on 3D acquisitions of the upper body, based on planar markers, which allows us to discriminate spatial displacements up to 2 mm in translation and 1 degree in rotation. We found a significant reduction of neck bending in interventions using visual aids, in particular for those performed with the microscope. We further investigated the impact of different postures on MSD risk using a widely adopted evaluation tool for ergonomic investigations of workplaces, named (RULA) Rapid Upper Limb Assessment. The analysis performed in this clinical trial is based on a 3D marker tracker that is able to follow a surgeon's upper limbs during interventions. The method highlighted pros and cons of different approaches.


Assuntos
Doenças Musculoesqueléticas , Doenças Profissionais , Recursos Audiovisuais , Odontologia , Ergonomia , Humanos , Doenças Musculoesqueléticas/diagnóstico , Postura
2.
Sensors (Basel) ; 20(24)2020 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-33327431

RESUMO

Internet of Things (IoT) applications play a relevant role in today's industry in sharing diagnostic data with off-site service teams, as well as in enabling reliable predictive maintenance systems. Several interventions scenarios, however, require the physical presence of a human operator: Augmented Reality (AR), together with a broad-band connection, represents a major opportunity to integrate diagnostic data with real-time in-situ acquisitions. Diagnostic information can be shared with remote specialists that are able to monitor and guide maintenance operations from a control room as if they were in place. Furthermore, integrating heterogeneous sensors with AR visualization displays could largely improve operators' safety in complex and dangerous industrial plants. In this paper, we present a complete setup for a remote assistive maintenance intervention based on 5G networking and tested at a Vodafone Base Transceiver Station (BTS) within the Vodafone 5G Program. Technicians' safety was improved by means of a lightweight AR Head-Mounted Display (HDM) equipped with a thermal camera and a depth sensor to foresee possible collisions with hot surfaces and dangerous objects, by leveraging the processing power of remote computing paired with the low latency of 5G connection. Field testing confirmed that the proposed approach can be a viable solution for egocentric environment understanding and enables an immersive integration of the obtained augmented data within the real scene.

3.
Sensors (Basel) ; 20(21)2020 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-33120975

RESUMO

The problem of performing remote biomedical measurements using just a video stream of a subject face is called remote photoplethysmography (rPPG). The aim of this work is to propose a novel method able to perform rPPG using single-photon avalanche diode (SPAD) cameras. These are extremely accurate cameras able to detect even a single photon and are already used in many other applications. Moreover, a novel method that mixes deep learning and traditional signal analysis is proposed in order to extract and study the pulse signal. Experimental results show that this system achieves accurate results in the estimation of biomedical information such as heart rate, respiration rate, and tachogram. Lastly, thanks to the adoption of the deep learning segmentation method and dependability checks, this method could be adopted in non-ideal working conditions-for example, in the presence of partial facial occlusions.


Assuntos
Biometria , Aprendizado Profundo , Fotopletismografia , Processamento de Sinais Assistido por Computador , Algoritmos , Face , Frequência Cardíaca , Humanos , Taxa Respiratória
4.
Materials (Basel) ; 12(3)2019 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-30736300

RESUMO

The aim of this paper is to introduce and characterize, both experimentally and numerically, three classes of non-traditional 3D infill patterns at three scales as an alternative to classical 2D infill patterns in the context of additive manufacturing and structural applications. The investigated 3D infill patterns are biologically inspired and include Gyroid, Schwarz D and Schwarz P. Their selection was based on their beneficial mechanical properties, such as double curvature. They are not only known from nature but also emerge from numerical topology optimization. A classical 2D hexagonal pattern has been used as a reference. The mechanical performance of 14 cylindrical specimens in compression is quantitatively related to stiffness, peak load and weight. Digital image correlation provides accurate full-field deformation measurements and insights into periodic features of the surface strain field. The associated variability, which is inherent to the production and testing process, has been evaluated for 3 identical Gyroid specimens. The nonlinear material model for the preliminary FEM analysis is based on tensile test specimens with 3 different slicing strategies. The 3D infill patterns are generally useful when the extrusion orientation cannot be aligned with the build orientation and the principal stress field, i.e., in case of generative design, such as the presented branching structure, or any complex shape and boundary condition.

5.
Materials (Basel) ; 12(3)2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30678305

RESUMO

Iron based shape memory alloys (Fe-SMA) have recently been used as active flexural strengthening material for reinforced concrete (RC) beams. Fe-SMAs are characterized by a shape memory effect (SME) which allows the recovery of previously induced plastic deformations through heating. If these deformations are restrained a recovery stress is generated by the SME. This recovery stress can be used to prestress a SMA applied as a strengthening material. This paper investigates the performance and the load deformation behavior of RC beams strengthened with mechanical end anchored unbonded Fe-SMA strips activated by sequentially infrared heating. The performance of a single loop loaded and a double loop loaded SMA strengthened RC beam are compared to an un-strengthened beam and a reference beam strengthened with commercially available structural steel. In these tests the SMA strengthened beam had the highest cracking load and the highest ultimate load. It is shown that the serviceability behavior of a concrete beam can be improved by a second thermal activation. The sequential heating procedure causes different temperature and stress states during activation along the SMA strip that have not been researched previously. The possible effect of this different temperature and stress states on metal lattice phase transformation is modeled and discussed. Moreover the role of the martensitic transformation during the cooling process on leveling the inhomogeneity of phase state in the overheated section is pointed out.

6.
Materials (Basel) ; 11(5)2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29723972

RESUMO

In the last decades, fastening systems have become an essential part of the construction industry. Post-installed mechanical anchors are frequently used in concrete members to connect them with other load bearing structural members, or to attach appliances. Their performance is limited by the concrete related failure modes which are highly influenced by the concrete mix design. This paper aims at investigating the effect that different aggregates used in the concrete mix have on the capacity of an undercut anchor under tensile quasi-static loading. Three concrete batches were cast utilising three different aggregate types. For two concrete ages (28 and 70 days), anchor tensile capacity and concrete properties were obtained. Concrete compressive strength, fracture energy and elastic modulus are used to normalize and compare the undercut anchor concrete tensile capacity employing some of the most widely used prediction models. For a more insightful comparison, a statistical method that yields also scatter information is introduced. Finally, the height and shape of the concrete cones are compared by highly precise and objective photogrammetric means.

7.
Materials (Basel) ; 10(8)2017 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-28786964

RESUMO

In recent years, post-installed anchors are widely used to connect structural members and to fix appliances to load-bearing elements. A bonded anchor typically denotes a threaded bar placed into a borehole filled with adhesive mortar. The high complexity of the problem, owing to the multiple materials and failure mechanisms involved, requires a numerical support for the experimental investigation. A reliable model able to reproduce a system's short-term behavior is needed before the development of a more complex framework for the subsequent investigation of the lifetime of fasteners subjected to various deterioration processes can commence. The focus of this contribution is the development and validation of such a model for bonded anchors under pure tension load. Compression, modulus, fracture and splitting tests are performed on standard concrete specimens. These serve for the calibration and validation of the concrete constitutive model. The behavior of the adhesive mortar layer is modeled with a stress-slip law, calibrated on a set of confined pull-out tests. The model validation is performed on tests with different configurations comparing load-displacement curves, crack patterns and concrete cone shapes. A model sensitivity analysis and the evaluation of the bond stress and slippage along the anchor complete the study.

8.
Rev. méd. Minas Gerais ; 20(3 supl.3): 33-35, jul.-set.2010. ilus
Artigo em Português | LILACS | ID: biblio-881010

RESUMO

O abdômen agudo hemorrágico (AAH) manifesta-se por dor abdominal de início súbito e intensidade moderada, sem sinais de irritação peritoneal e de choque hipovolêmico. Este trabalho relata a evolução do AAH em paciente com leucemia pró-mielocítica aguda (LPMA), subtipo da leucemia mieloide aguda (LMA). Trata-se de paciente feminino, 25 anos de idade, com diagnóstico recente de LPMA, admitida no Hospital Vila da Serra.(AU)


Acute Hemorrhagic Abdomen (AHA) appears with a sudden abdominal pain, with moderate intensity, without symptoms of peritoneal irritation and/or hypovolemic shock. Acute Promyelocytic Leukemia (APL) is a subtype of Acute Myeloid Leukemia (AML). Here we describe a case of a 25 years old female patient with AHA and APL. The patient was recently diagnosticated with APL, and was admitted to the Vila da Serra Hospital with AHA.(AU)


Assuntos
Humanos , Feminino , Adulto , Leucemia Promielocítica Aguda/complicações , Abdome Agudo/cirurgia , Complicações Pós-Operatórias/tratamento farmacológico , Radiografia Torácica , Leucemia Promielocítica Aguda/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...